Home Trace Heating Sectors Industrial Applications Heating Cables BTV Self Regulating Heating Cables Raychem 5BTV2-CR Self Regulating Trace Heating Cable

Raychem 5BTV2-CR Self Regulating Trace Heating Cable

Quick Find: 1396
Part Number: 414809-000
£16.30
£19.56 inc VAT
Large order Bulk Discounts Available upon request
call us now on 01473 276672 to find out more!
Delivery Available: FREE Next Working Day
Order now for delivery by Friday 20th October
our next day delivery cut off time of 4:00 PM has now passed.
RangePentair Raychem BTV CR
Model5BTV2-CR
WeightWeight 0.11 Kg

Electrical heat-tracing for frost protection without steam cleaning.

The BTV-family of self-regulating, parallel circuit heating cables is used for frost protection of pipes and vessels.

It can also be used for process temperature maintenance up to 65°C.

Application

Area Classification:

  • Hazardous, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust)
  • Ordinary

Traced surface type:

  • Carbon Steel
  • Stainless Steel
  • Plastic
  • Painted or unpainted metal

Chemical resistance:

  • For organic corrosives: use -CT (fluoropolymer outer jacket)
  • For mild inorganic solutions: use -CR (modified polyolefin outer jacket)
  • For aggressive organics and corrosives consult your local Pentair representative

Approvals

The BTV heating cables are approved for use in hazardous areas by PTB and Baseefa Ltd.

  • PTB 09 ATEX 1115 X & Baseefa06ATEX0183X
  • II 2 G Ex e II T6 & II 2 D Ex tD A21 IP66 T80°C
  • IECEx PTB 09.0056X & IECEx BAS 06.0043X
  • Ex e II T6 & Ex tD A21 IP66 T80°C

The BTV heating cables are approved by DNV for use on ships and mobile offshore units. DNV Certificate No. E-11564

Electrical Protection Sizing Start Up Temperature Maximum Heating Cable length per circuit(M)
16 A -20°c 155 110 70 45
+10°c 200 160 110 65
25 A -20°c 195 140 90 55
+10°c 200 160 125 85
32 A -20°c 200 160 110 70
+10°c 200 160 125 105
40 A -20°c 200 160 125 90
+10°c 200 160 125 110

The above numbers are for circuit length estimation only. For more detailed information please use the Pentair TraceCalc software or Contact your local Pentair representative.

Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.

Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.

Technical Specifications
Brand Raychem
Maximum maintain or continuous exposure temperature (power on) 110 °C
Minimum bend radius At -60°C: 35 mm
Minimum bend radius At 20°C: 13 mm
Minimum installation temperature -60 °C
Nominal power output 16
Temperature Classification T4 in accordance with European Standard EN 60079-30-1 5.1.13
Thickness 5.5 mm
Width 10.5 mm

Frequently Asked Questions

We make every effort in answering your questions. Below is a list of those questions we are frequently asked. Click on a question to expand its answer.

What is self regulating heating tape?

Self limiting / self regulating heating tape adjusts heat output to equal the heat loss from the pipe work. As pipe temperature falls the electrical conductivity of the semi-conductive core increas...

Read more

Can you design a full surface heating system for me?

Yes, utilising our in-house design facilities, we can design your complete trace heating requirement.

Read more

Can I use heat trace on plastic pipes?

Yes, when using trace heating on plastic pipes ensure that ATE- 180 aluminium tape is used to help disperse the heat around the pipe.

Read more

Do I need to use thermal insulation?

Yes, thermal insulation is required on all heat trace applications. Without insulation, surface heat losses can increase approximately 4-5 times.

Read more

Do I have to spiral the trace heating onto the pipe?

Most applications can simply be straight traced, reducing costs of materials and installation time without compromising on operational requirements.

Read more

How do I terminate the heating cable?

Full termination instructions are provided with all our heating tapes

Read more

Do I have to allow extra heat for pumps and valves?

If the surface area of the pump is substantially greater than that of the adjoining pipework then extra heating cable may need to be considered (depending on wattage of cable installed). Pumps and ...

Read more

Does my trace heating system require maintenance?

Generally, no maintenance of our trace heating systems is required but it is recommended that the system is checked for operational and electrical integrity periodically or prior to the winter or p...

Read more

How do I test my trace heating system is working properly?

System checks depend on the system installed, constant wattage systems can be fully checked for insulation resistance and continuity. Self regulating systems can only be checked for insulation resi...

Read more

What is Heat Trace?

This is used for a pipe freeze protection application. Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels. Trace heat...

Read more

What is heat tape for water pipes?

When water pipes are exposed to cold temperatures either outdoors, underground or in small spaces, you can protect them from freezing by wrapping them with heat tape. Heating tape is actually a cor...

Read more

Look for similar items by category

More from the Pentair Raychem BTV CR range...

Raychem 5BTV2-CR Self Regulating Trace Heating Cable Product Discussion