Raychem HSQ1M4000 Stainless Steel Sheathed Series Heating Cable 4000 ?/km ATEX

More from MI Series Heating Cables HSQ

Raychem HSQ1M4000 Stainless Steel Sheathed Series Heating Cable 4000 ?/km ATEX
Raychem HSQ1M4000 Stainless Steel Sheathed Series Heating Cable 4000 ?/km ATEX
nVent

Quick Find: 9530
Part Code: HSQ1M4000

Stock Available: 0 Units

Selected Total: £0.00

    Price on Application

    Please contact our sales team for pricing.

    Call us on

    01473 276672

    Contact us online

    Request pricing

    Product overview

    Raychem HSQ mineral insulated (MI) Stainless steel series heating cables are suited for use in hazardous areas. The Stainless steel sheath offers excellent corrosive properties against a wide range of organic acids and alkalis in combination with a high temperature withstand capability.

    HSQ cables are typically used in bitumen plants, gas plants, oil refineries, reactors and vessels, sodium loops and a wide variety of other heat-tracing applications where temperature resistance, power output and durability are paramount. The heating cables can be used for exposure temperatures up to 700°C and a typical power output up to 150 W/m. Higher temperatures and power outputs can be achieved, contact Pentair for assistance.

    The heating cables are offered as bulk cables as well as factory-terminated heating units employing brazing or laser welding techniques to ensure optimum quality of the connections. The offering is completed with a full range of components for installation, connection and splicing of the heating cables.

    Application

    Area Classification

    • Hazardous areas, Zone 1 or Zone 2 (Gas) or Zone 21 or Zone 22 (Dust)
    • Ordinary areas

    Approvals

    System (Heating Units):

    • Baseefa02ATEX0046X
    • II 2GD Ex e II T6 to T1 Ex tD A21 IP6X
    • Actual T class temperature determined by design

    Bulk cable:

    • Baseefa02ATEX0045U
    • II 2G Ex e II
    Order ReferenceNominal Resistance
    [Ω/km @ 20°C]
    Temp Coefficient
    [x 10-3 /K]
    Outer Diameter
    [mm]
    Max Coil Length
    (Kg/Km)
    HSQ1M10K100000.093.2717
    HSQ1M630063000.093.2717
    HSQ1M400040000.093.2717
    HSQ1M250025000.093.4639
    HSQ1M160016000.093.6572
    HSQ1M100010000.093.9499
    HSQ1M6306300.094.3405
    HSQ1M4004000.094.7342
    HSQ1M2502500.095.3271
    HSQ1M1601600.096.5180

    Brass glands are standard on all heating units. Other materials are possible, contact Pentair for more information.

    Delivery length of bulk cable on coil depends on type of resistance and is limited by max. coil length as indicated in the table on top. Factory terminated elements are limited by a max. weight of 50kg, however to ensure practical and safe on-site handling, it is strongly recommended to limit element lengths to 25 - 30kg. Not all resistances are standard items and as such may not be in stock. Contact Pentair to confirm lead time. Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.

    Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.
    Also refer to the components section for more details on heating units, accessories and nomenclatures.

    Technical specifications

    BrandnVent
    Cable sheath material321 Stainless Steel
    Conductor MaterialNichrome
    Earth Leakage3 mA/100m (Nominal at 20°C, 230 Vac, 50-60 Hz)
    Max Exposure Temp700°C (Laser Welded Heating Units)
    Max Exposure Temp450°C (Brazed Heating Units)
    Max Exposure Temp700°C (Heating Cables)
    Min Bending Radius6 x outer diameter at -60°C
    Min Cable Spacing25mm for hazardous Areas
    Minimum installation temperature-60 °C