Raychem HAF2M29.5K Alloy 825 Sheathed Series Heating Cable (Dual, 300V) 29500 ?/km ATEX

More from MI Series Heating Cables HAx Dual Conductor, 300/500V

Raychem HAF2M29.5K Alloy 825 Sheathed Series Heating Cable (Dual, 300V) 29500 ?/km ATEX
Raychem HAF2M29.5K Alloy 825 Sheathed Series Heating Cable (Dual, 300V) 29500 ?/km ATEX
nVent

Quick Find: 9564
Part Code: 32SF2900

Stock Available: 0 Units

Selected Total: £0.00

    Price on Application

    Please contact our sales team for pricing.

    Call us on

    01473 276672

    Contact us online

    Request pricing

    Product overview

    Raychem HAx mineral insulated (MI) Alloy 825 series heating cables are suitable for use in hazardous areas. They have been designed for use in freeze protection and temperature maintenance applications of pipes, tanks and other equipment.

    MI heating cables of the HAx-series offer an ideal combination of ruggedness, high temperature withstand capability and corrosion resistance and can therefore be used for a wide variety of heat-tracing applications, in particular for applications with high power requirements and for temperatures exceeding the capabilities of polymer insulated (PI) series heating cables.

    The heating cables can be used for exposure temperatures of up to 700°C and a typical power output of up to 270 W/m. Higher temperatures and power outputs can be achieved, contact Pentair for assistance.

    HAx mineral insulated (MI) heating cables are available as single and dual conductor construction and in a very wide range of resistances. The use of dual conductor heating cables can significantly reduce total installed cost and simplifies installation, in particular for small pipes and instrument tubing.

    The heating cables are offered as bulk cable as well as factory terminated heating units employing brazing and laser welding technology. The offering is completed with a full range of components for installation, connection and splicing of the heating cables.

    Application

    Area Classification:

    • Hazardous area, Zone 1 or Zone 2 (Gas) or Zone 21 or zone 22 (Dust)
    • Ordinary

    Approvals

    System (Heating Units):

    • Baseefa02ATEX0046X
    • II 2GD Ex e II T6 to T1 Ex tD A21 IP6X
    Order ReferenceNominal Resistance
    [Ω/km @ 20°C]
    Temp Coefficient
    [x 10-3 /K]
    Outer Diameter
    [mm nom.]
    Max Coil Length
    (Kg/Km)
    Part Number
    HAF2M36K360000.0911.562832SF1110
    HAF2M29.5K295000.099.754232SF2900
    HAF2M24.5K245000.098.243132SF2750
    HAA2M19.7K197000.096.563232SA2600
    HAA2M13.2K132000.095.550032SA2400
    HAA2M900090000.094.950132SA2275
    HAA2M660066000.094.432932SA2200
    HAA2M560056000.094.238432SA2170
    HAB2M375037500.044.131532SB2114
    HAB2M230023000.043.941932SB3700
    HAQ2M156015600.53.931732SQ3472
    HAQ2M124012400.54.331732SQ3374
    HAQ2M9659650.53.931432SQ3293
    HAQ2M6606600.53.850332SQ3200
    HAQ2M4954950.54.141932SQ3150
    HAQ2M3303300.54.233232SQ3100
    HAP2M2402401.33.931632SP4734
    HAP2M1901901.33.731732SP4583
    HAP2M1501501.33.831532SP4458
    HAC2M1051053.93.831532SC4324
    HAF2N36K360000.095.222962SF1110
    HAF2N29.5K295000.095.522962SF2900
    HAF2N19.7K197000.095.523062SF2600
    HAA2N13.6K136000.095.818662SA2414
    HAF2N660066000.096.317762SF2200
    HAT2N375037500.045.718662ST2115
    HAB2N230023000.56.815162SB3700
    HAQ2N167016700.55.719462SQ3505
    HAQ2N9409400.56.017662SQ3286
    HAQ2N6606600.56.317762SQ3200
    HAQ2N4954950.56.317762SQ3150
    HAQ2N3303301.36.715262SQ3100
    HAP2N2552551.36.415162SP4775
    HAP2N1851851.36.713862SP4561
    HAP2N1301301.37.112462SP4402
    HAP2N92923.97.511062SP4281
    HAC2N66663.97.513162SC4200
    HAC2N43433.97.911562SC4130
    HAC2N27273.98.79862SC5818
    HAC2N17173.99.28162SC5516
    HAC2N10.510.23.910.26762SC5324
    HAC2N6.612.63.912.24662SC5204
    HAC2N4.313.83.913.814362SC5128
    HAA1N656565650.0853.751961SA2200
    HAA1N525052500.0854.143661SA2160
    HAA1N430043000.0854.141561SA2130
    HAA1N330033000.0854.041661SA2100
    HAA1N280028000.0854.336861SA3850
    HAA1N230023000.0854.141761SA3700
    HAA1N164016400.0854.532961SA3500
    HAT1N9209200.184.631761ST3280
    HAB1N6606600.044.633061SB3200
    HAB1N5005000.044.633161SB3150
    HAQ1N3903900.54.731761SQ3118
    HAQ1N2402400.54.731461SQ4732
    HAQ1N1901900.54.634261SQ4581
    HAP1N1551551.34.731661SP4467
    HAP1N1201201.34.731461SP4366
    HAP1N95951.34.731561SP4290
    HAP1N76761.34.634261SP4231
    HAP1N60601.34.731661SP4183
    HAP1N48481.34.731761SP4145
    HAP1N37371.34.733561SP4113
    HAC1N21.321.33.94.930561SC5651
    HAC1N13.513.53.95.129461SC5409
    HAC1N8.58.53.95.623361SC5258
    HAC1N5.35.33.96.915861SC5162
    HAC1N3.33.33.96.417161SC5102
    HAC1N22.03.98.111561SC6640

    All cold lead cables can be used for up to 600 Vac and use copper conductors with a temperature coefficient of 3.9 x 10-3 1/K. * For details on the different heating unit designs, refer to page 179.
    Delivery length of bulk cable on coil depends on type of resistance and is limited by max. coil length as indicated in the table on top.

    Factory terminated elements are limited by a max. weight of 50kg, however to ensure practical and safe on-site handling, it is strongly recommended to limit element lengths to 25 - 30kg. Not all resistances are standard items and as such may not be in stock. Contact Pentair to confirm lead time. Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.


    Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.

    Technical specifications

    BrandnVent
    Cable sheath materialAlloy 825
    Conductor MaterialVarious Alloys and Copper
    Earth Leakage3 mA/100m (Nominal at 20°C, 230 Vac, 50-60 Hz)
    Max Exposure Temp700°C (Heating Cables)
    Max Exposure Temp550°C (Brazed Heating Units)
    Max Exposure Temp700°C (Laser Welded Heating Units)
    Min Bending Radius6 x outer diameter at -60°C
    Min Cable Spacing25mm for hazardous Areas