Model HAA1N2800

Raychem HAx mineral insulated (MI) Alloy 825 series heating cables are suitable for use in hazardous areas. They have been designed for use in freeze protection and temperature maintenance applications of pipes, tanks and other equipment.

MI heating cables of the HAx-series offer an ideal combination of ruggedness, high temperature withstand capability and corrosion resistance and can therefore be used for a wide variety of heat-tracing applications, in particular for applications with high power requirements and for temperatures exceeding the capabilities of polymer insulated (PI) series heating cables.

The heating cables can be used for exposure temperatures of up to 700°C and a typical power output of up to 270 W/m. Higher temperatures and power outputs can be achieved, contact Pentair for assistance.

HAx mineral insulated (MI) heating cables are available as single and dual conductor construction and in a very wide range of resistances. The use of dual conductor heating cables can significantly reduce total installed cost and simplifies installation, in particular for small pipes and instrument tubing.

The heating cables are offered as bulk cable as well as factory terminated heating units employing brazing and laser welding technology. The offering is completed with a full range of components for installation, connection and splicing of the heating cables.

Application

Area Classification:

  • Hazardous area, Zone 1 or Zone 2 (Gas) or Zone 21 or zone 22 (Dust)
  • Ordinary

Approvals

System (Heating Units):

  • Baseefa02ATEX0046X
  • II 2GD Ex e II T6 to T1 Ex tD A21 IP6X
Order ReferenceNominal Resistance
[Ω/km @ 20°C]
Temp Coefficient
[x 10-3 /K]
Outer Diameter
[mm nom.]
Max Coil Length
(Kg/Km)
Part Number
HAF2M36K360000.0911.562832SF1110
HAF2M29.5K295000.099.754232SF2900
HAF2M24.5K245000.098.243132SF2750
HAA2M19.7K197000.096.563232SA2600
HAA2M13.2K132000.095.550032SA2400
HAA2M900090000.094.950132SA2275
HAA2M660066000.094.432932SA2200
HAA2M560056000.094.238432SA2170
HAB2M375037500.044.131532SB2114
HAB2M230023000.043.941932SB3700
HAQ2M156015600.53.931732SQ3472
HAQ2M124012400.54.331732SQ3374
HAQ2M9659650.53.931432SQ3293
HAQ2M6606600.53.850332SQ3200
HAQ2M4954950.54.141932SQ3150
HAQ2M3303300.54.233232SQ3100
HAP2M2402401.33.931632SP4734
HAP2M1901901.33.731732SP4583
HAP2M1501501.33.831532SP4458
HAC2M1051053.93.831532SC4324
HAF2N36K360000.095.222962SF1110
HAF2N29.5K295000.095.522962SF2900
HAF2N19.7K197000.095.523062SF2600
HAA2N13.6K136000.095.818662SA2414
HAF2N660066000.096.317762SF2200
HAT2N375037500.045.718662ST2115
HAB2N230023000.56.815162SB3700
HAQ2N167016700.55.719462SQ3505
HAQ2N9409400.56.017662SQ3286
HAQ2N6606600.56.317762SQ3200
HAQ2N4954950.56.317762SQ3150
HAQ2N3303301.36.715262SQ3100
HAP2N2552551.36.415162SP4775
HAP2N1851851.36.713862SP4561
HAP2N1301301.37.112462SP4402
HAP2N92923.97.511062SP4281
HAC2N66663.97.513162SC4200
HAC2N43433.97.911562SC4130
HAC2N27273.98.79862SC5818
HAC2N17173.99.28162SC5516
HAC2N10.510.23.910.26762SC5324
HAC2N6.612.63.912.24662SC5204
HAC2N4.313.83.913.814362SC5128
HAA1N656565650.0853.751961SA2200
HAA1N525052500.0854.143661SA2160
HAA1N430043000.0854.141561SA2130
HAA1N330033000.0854.041661SA2100
HAA1N280028000.0854.336861SA3850
HAA1N230023000.0854.141761SA3700
HAA1N164016400.0854.532961SA3500
HAT1N9209200.184.631761ST3280
HAB1N6606600.044.633061SB3200
HAB1N5005000.044.633161SB3150
HAQ1N3903900.54.731761SQ3118
HAQ1N2402400.54.731461SQ4732
HAQ1N1901900.54.634261SQ4581
HAP1N1551551.34.731661SP4467
HAP1N1201201.34.731461SP4366
HAP1N95951.34.731561SP4290
HAP1N76761.34.634261SP4231
HAP1N60601.34.731661SP4183
HAP1N48481.34.731761SP4145
HAP1N37371.34.733561SP4113
HAC1N21.321.33.94.930561SC5651
HAC1N13.513.53.95.129461SC5409
HAC1N8.58.53.95.623361SC5258
HAC1N5.35.33.96.915861SC5162
HAC1N3.33.33.96.417161SC5102
HAC1N22.03.98.111561SC6640

All cold lead cables can be used for up to 600 Vac and use copper conductors with a temperature coefficient of 3.9 x 10-3 1/K. * For details on the different heating unit designs, refer to page 179.
Delivery length of bulk cable on coil depends on type of resistance and is limited by max. coil length as indicated in the table on top.

Factory terminated elements are limited by a max. weight of 50kg, however to ensure practical and safe on-site handling, it is strongly recommended to limit element lengths to 25 - 30kg. Not all resistances are standard items and as such may not be in stock. Contact Pentair to confirm lead time. Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.


Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.

Frequently asked questions

Can I use heat trace on plastic pipes?

Yes, when using trace heating on plastic pipes ensure that ATE- 180 aluminium tape is used to help disperse the heat around the pipe.

Read more

Can you design a full surface heating system for me?

Yes, utilising our in-house design facilities, we can design your complete trace heating requirement.

Read more

Do I have to allow extra heat for pumps and valves?

If the surface area of the pump is substantially greater than that of the adjoining pipework then extra heating cable may need to be considered (depending on wattage of cable installed). Pumps and ...

Read more

Do I have to spiral the trace heating onto the pipe?

Most applications can simply be straight traced, reducing costs of materials and installation time without compromising on operational requirements.

Read more

Do I need to use thermal insulation?

Yes, thermal insulation is required on all heat trace applications. Without insulation, surface heat losses can increase approximately 4-5 times.

Read more

Does my trace heating system require maintenance?

Generally, no maintenance of our trace heating systems is required but it is recommended that the system is checked for operational and electrical integrity periodically or prior to the winter or p...

Read more

How do I terminate the heating cable?

Full termination instructions are provided with all our heating tapes

Read more

How do I test my trace heating system is working properly?

System checks depend on the system installed, constant wattage systems can be fully checked for insulation resistance and continuity. Self regulating systems can only be checked for insulation resi...

Read more

What is heat tape for water pipes?

When water pipes are exposed to cold temperatures either outdoors, underground or in small spaces, you can protect them from freezing by wrapping them with heat tape. Heating tape is actually a cor...

Read more

What is Heat Trace?

This is used for a pipe freeze protection application. Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels. Trace heat...

Read more

What is self regulating heating tape?

Self limiting / self regulating heating tape adjusts heat output to equal the heat loss from the pipe work. As pipe temperature falls the electrical conductivity of the semi-conductive core increas...

Read more

Look for similar items by category