Raychem 4XTV2-CT-T3 Self Regulating Trace Heating Cable

More from XTV Self Regulating Heating Cables

Raychem 4XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 4XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 4XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 4XTV2-CT-T3 Self Regulating Trace Heating Cable
nVent

Quick Find: 1778
Part Code: 002735-000

This product is currrently out of stock.

This product is currrently out of stock.
Sign up to be notified when this product is back in stock.


Free Delivery Available
£35.90
£43.08 inc VAT
Stock Available: 0 Units

Selected Total: £0.00


    Qty

    Product overview

    Electrical heat-tracing for process temperature maintenance applications up to 121°C which may be subject to steam cleaning.

    The XTV family of self-regulating, parallel circuit heating cables is used for process temperature maintenance of pipes and vessels.;

    It can also be used for frost protection of large pipes and for applications requiring high temperature exposure capability.

    Application:

    Area Classification:

    • Hazardous, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust)
    • Ordinary

    Traced Surface Type:

    • Carbon steel
    • Stainless steel
    • Painted or unpainted metal

    Chemical Resistance:

    • Organics and corrosives
    • For aggressive organics and corrosives consult your local Pentair representative

    Approvals

    The XTV heating cables are approved for use in hazardous areas by PTB and Baseefa Ltd.

    • PTB 09 ATEX 1118 X & Baseefa06ATEX0184X
    • II 2G Ex e II T* & II 2D Ex tD A21 IP66 T*
    • IECEx PTB 09.0059X & IECEx BAS 06.0044X
    • Ex e II T* & Ex tD A21 IP66 T*

    *See approval schedule

    Electrical Protection SizingStart Up TemperatureMaximum Heating Cable length per circuit(M)
    16 A-20°c14590655540
    +10°c170105756045
    25 A-20°c2251451058565
    +10°c2451651209570
    32 A-20°c24517513510580
    +10°c24517514012590
    40 A-20°c245175140135110
    +10°c245175140135110

    The above numbers are for circuit length estimation only. For more detailed information please use the Pentair TraceCalc software or Contact your local Pentair representative.

    Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.

    Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.

    Technical specifications

    BrandnVent
    Maximum maintain or continuous exposure temperature (power on)120 °C
    Minimum bend radiusAt 20°C: 13 mm
    Minimum bend radiusAt -60°C: 51 mm
    Minimum installation temperature-60 °C
    Model4XTV2-CT-T3
    Temperature ClassificationT3: 4XTV2-CT-T3, 8XTV2-CT-T3, 12XTV2-CT-T3, 12XTV2-CT-T3, 15XTV2-CT-T3
    Temperature ClassificationT2: 20XTV2-CT-T2
    Thickness7.2 mm
    Width11.7 mm

    Videos

    Product downloads

    Declaration of Conformity

    File Size: 418.82 KB