Raychem 20XTV2-CT-T3 Self Regulating Trace Heating Cable

Raychem 20XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 20XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 20XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 20XTV2-CT-T3 Self Regulating Trace Heating Cable

Quick Find: 1063
Part Code: 849015-000

Free Delivery Available
£38.16
£45.79 inc VAT
List Price: £42.40
Qty

Estimated delivery: 1 working days

Product overview

Range Pentair Raychem XTV Self Regulating Heating Cable
Model 20XTV2-CT-T3
Weight 0.18 Kg

Electrical heat-tracing for process temperature maintenance applications up to 121°C which may be subject to steam cleaning.

The XTV family of self-regulating, parallel circuit heating cables is used for process temperature maintenance of pipes and vessels.;

It can also be used for frost protection of large pipes and for applications requiring high temperature exposure capability.

Application:

Area Classification:

  • Hazardous, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust)
  • Ordinary

Traced Surface Type:

  • Carbon steel
  • Stainless steel
  • Painted or unpainted metal

Chemical Resistance:

  • Organics and corrosives
  • For aggressive organics and corrosives consult your local Pentair representative

Approvals

The XTV heating cables are approved for use in hazardous areas by PTB and Baseefa Ltd.

  • PTB 09 ATEX 1118 X & Baseefa06ATEX0184X
  • II 2G Ex e II T* & II 2D Ex tD A21 IP66 T*
  • IECEx PTB 09.0059X & IECEx BAS 06.0044X
  • Ex e II T* & Ex tD A21 IP66 T*

*See approval schedule

Electrical Protection SizingStart Up TemperatureMaximum Heating Cable length per circuit(M)
16 A-20°c14590655540
+10°c170105756045
25 A-20°c2251451058565
+10°c2451651209570
32 A-20°c24517513510580
+10°c24517514012590
40 A-20°c245175140135110
+10°c245175140135110

The above numbers are for circuit length estimation only. For more detailed information please use the Pentair TraceCalc software or Contact your local Pentair representative.

Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.

Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.

Technical specifications

Maximum maintain or continuous exposure temperature (power on)120 °C
Minimum bend radiusAt -60°C: 51 mm
Minimum bend radiusAt 20°C: 13 mm
Minimum installation temperature-60 °C
Model20XTV2-CT-T3
Temperature ClassificationT3: 4XTV2-CT-T3, 8XTV2-CT-T3, 12XTV2-CT-T3, 12XTV2-CT-T3, 15XTV2-CT-T3
Temperature ClassificationT2: 20XTV2-CT-T2
Thickness7.2 mm
Width11.7 mm

Product downloads

Declaration of Conformity

File Size: 418.82 KB

More from the Pentair Raychem XTV Self Regulating Heating Cable range...

Need help?
Chat with us

We are online and available to answer your sales and customer services queries.

Enter your details and click begin to speak with one of our advisors.