Raychem 15XTV2-CT-T3 Self Regulating Trace Heating Cable

Raychem 15XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 15XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 15XTV2-CT-T3 Self Regulating Trace Heating Cable
Raychem 15XTV2-CT-T3 Self Regulating Trace Heating Cable

Quick Find: 1446
Part Code: 214999-000

Free Delivery Available
£36.27
£43.52 inc VAT
List Price: £40.30
Qty

Available Delivery: Free Next Day Delivery

Order now for delivery by Wednesday 19th December if you place your order before 3:00 PM today

Large order Bulk Discounts Available upon request call us now on 01473 276672 to find out more!

Product overview

Range Pentair Raychem XTV Self Regulating Heating Cable
Model 15XTV2-CT-T3

Electrical heat-tracing for process temperature maintenance applications up to 121°C which may be subject to steam cleaning.

The XTV family of self-regulating, parallel circuit heating cables is used for process temperature maintenance of pipes and vessels.;

It can also be used for frost protection of large pipes and for applications requiring high temperature exposure capability.

Application:

Area Classification:

  • Hazardous, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust)
  • Ordinary

Traced Surface Type:

  • Carbon steel
  • Stainless steel
  • Painted or unpainted metal

Chemical Resistance:

  • Organics and corrosives
  • For aggressive organics and corrosives consult your local Pentair representative

Approvals

The XTV heating cables are approved for use in hazardous areas by PTB and Baseefa Ltd.

  • PTB 09 ATEX 1118 X & Baseefa06ATEX0184X
  • II 2G Ex e II T* & II 2D Ex tD A21 IP66 T*
  • IECEx PTB 09.0059X & IECEx BAS 06.0044X
  • Ex e II T* & Ex tD A21 IP66 T*

*See approval schedule

Electrical Protection SizingStart Up TemperatureMaximum Heating Cable length per circuit(M)
16 A-20°c14590655540
+10°c170105756045
25 A-20°c2251451058565
+10°c2451651209570
32 A-20°c24517513510580
+10°c24517514012590
40 A-20°c245175140135110
+10°c245175140135110

The above numbers are for circuit length estimation only. For more detailed information please use the Pentair TraceCalc software or Contact your local Pentair representative.

Pentair requires the use of a 30 mA residual current device to provide maximum safety and protection from fire.

Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven.

Technical specifications

Maximum maintain or continuous exposure temperature (power on)120 °C
Minimum bend radiusAt 20°C: 13 mm
Minimum bend radiusAt -60°C: 51 mm
Minimum installation temperature-60 °C
Model15XTV2-CT-T3
Temperature ClassificationT3: 4XTV2-CT-T3, 8XTV2-CT-T3, 12XTV2-CT-T3, 12XTV2-CT-T3, 15XTV2-CT-T3
Temperature ClassificationT2: 20XTV2-CT-T2
Thickness7.2 mm
Width11.7 mm

Product downloads

Declaration of Conformity

File Size: 418.82 KB

Frequently asked questions

Can I use heat trace on plastic pipes?

Yes, when using trace heating on plastic pipes ensure that ATE- 180 aluminium tape is used to help disperse the heat around the pipe.

Read more

Can you design a full surface heating system for me?

Yes, utilising our in-house design facilities, we can design your complete trace heating requirement.

Read more

Do I have to allow extra heat for pumps and valves?

If the surface area of the pump is substantially greater than that of the adjoining pipework then extra heating cable may need to be considered (depending on wattage of cable installed). Pumps and ...

Read more

Do I have to spiral the trace heating onto the pipe?

Most applications can simply be straight traced, reducing costs of materials and installation time without compromising on operational requirements.

Read more

Do I need to use thermal insulation?

Yes, thermal insulation is required on all heat trace applications. Without insulation, surface heat losses can increase approximately 4-5 times.

Read more

Does my trace heating system require maintenance?

Generally, no maintenance of our trace heating systems is required but it is recommended that the system is checked for operational and electrical integrity periodically or prior to the winter or p...

Read more

How do I terminate the heating cable?

Full termination instructions are provided with all our heating tapes

Read more

How do I test my trace heating system is working properly?

System checks depend on the system installed, constant wattage systems can be fully checked for insulation resistance and continuity. Self regulating systems can only be checked for insulation resi...

Read more

What is heat tape for water pipes?

When water pipes are exposed to cold temperatures either outdoors, underground or in small spaces, you can protect them from freezing by wrapping them with heat tape. Heating tape is actually a cor...

Read more

What is Heat Trace?

This is used for a pipe freeze protection application. Electric heat tracing, heat tape or surface heating, is a system used to maintain or raise the temperature of pipes and vessels. Trace heat...

Read more

What is self regulating heating tape?

Self limiting / self regulating heating tape adjusts heat output to equal the heat loss from the pipe work. As pipe temperature falls the electrical conductivity of the semi-conductive core increas...

Read more

More from the Pentair Raychem XTV Self Regulating Heating Cable range...